Available Air Conditioning Equipment:
APC AirFlow AC
| Part Number |
Description |
Tons |
| AFX-210W-4 |
Downflow 10 ton AC, water cooler system, 460 volt, 3 phase, (used take/out equipment) Data Guard Microprocuror Controls, Steam Humidifier, Smoke detector, Reheat 3 stages Mfg date 2002 |
10 |
Data Aire AC
| Part Number |
Description |
Tons |
| DAWU-2034E |
Upflow (New surplus Mfg 2001), 20 Ton AC, water cooled, 480 volt, 3 phase, free cooling coil, Microprocessor control, steam Humidifier, 3 stages reheat, smoke detector, Electrical Disconnect switch. |
20 |
| DAAD-2034 |
Downflow 20 ton Air Cooled, Data Aire AC, 460 Volt, 3 phase (New Surplus Mfg 2000) 20 tons, Microprocessor Controls, Steam Humidifier, Smoke detector, Reheat 3 stages, Electrical disconnect switch, floor stand if required. |
20 |
| DAAD-2634 |
Downflow 26 ton Air Cooled, Data Aire AC, 460 Volt, 3 phase (New Surplus Mfg 2000) 26 tons, Microprocessor Controls, Steam Humidifier, Smoke detector, Reheat 3 stages, Electrical disconnect switch, floor stand if required. |
26 |
| DAGD-2634 |
Downflow 26 ton Gylcol Cooled, Data Aire AC, 460 Volt, 3 phase (New Surplus Mfg 2000) 26 tons, Microprocessor Controls, Steam Humidifier, Smoke detector, Reheat 3 stages, Electrical disconnect switch, floor stand if required. |
26 |
| DAFC-5034 |
Drycooler, 5 fan, Data Aire, 460 Volt, 3 phase (New Surplus Mfg 2000), fan speed controls 30 ton. |
30 |
Liebert AC
| Part Number |
Description |
Tons |
| BU-046WG-AAEI |
5 ton Upflow water/glycol Challenger series w/plenum |
3 |
| BF-46W/G-AAEI |
5 ton Downflow water/glycol Challenger series |
3 |
| BF-067A-AAEI |
Downflow (Mfg 2002), 5 Ton AC, air cooler with CD-083 1 fan condenser, 480 Volt, 3 phase, Microprocessor control, Humidifier, Reheat, smoke detector, Electrical Disconnect switch. |
5 |
| VH-075A-AAEI |
6 Ton UP-flow, 480 Volt New Surplus System, Includes Electrical disconnect switch, compressor Unloaders, Infrared Humidifier, Electric reheat, smoke detector, condensate pump. |
6 |
| VH-127WG-AAOO |
Upflow (Mfg 2003), 10 Ton AC, water cooled, 460 volt, 3 phase, Microprocessor control, smoke detector |
10 |
| UH-147C-AAO |
Upflow (Mfg 2004), 10 Ton AC, Chilled water, 480 Volt, 3 phase, Microprocessor control, Humidifier, Reheat, smoke detector, Electrical Disconnect switch |
10 |
| DH-125A-UAAEI |
Liebert AC, Air Cooled, 480 Volt, 3 phase, Humidifier, Reheat, Mfg date 03/02, downflow |
10 |
| VH-138WG-AAEI |
Upflow (Mfg 2005) New Surplus, 12 Ton AC, water cooled, 460 volt, 3 phase, Microprocessor control, smoke detector, Humidifier, Electrical Reheat. |
12 |
| DH-199A-UCAEI |
15 Ton Liebert Air Cooled System 3, 208 Volt, 3 phase, Humidifier, re-heat, electrical disconnect switch, compressor Unloaders, Floor Stands, Mfg 2001, 2003. Also supplied with matching Condenser DCDL-205, 2 Fan, Fan speed controls to -20 degree. |
15 |
| VH-199A-AAEI |
Liebert 15 Ton, Air Cooled, 460 Volt 3P, Mfg D-00. Supplied with: Electric Disconnect Switch, Humidifier, Reheat, Condensate pump, discharge Air Plenums, System includes outdoor 3 fan condenser, model CDL-308LA with Lee Temp controls. |
15 |
| FD-199A-UAAEI |
Reconditioned Mfg 1999, 15 Ton Downflow.,
DX System with DCDC308L, 3 Fan Condenser.
Electric Disconnect Switch, Smoke Detector, Humidifier, Reheat, Floor Stands |
15 |
| UH-075AAM |
Liebert 8 Ton, Air Cooled, 460 Volt 3P, Mfg 2000, New Surplus Unit: Supplied with: Electric Disconnect Switch, Humidifier, Reheat. |
8 |
Stulz AC
| Part Number |
Description |
Tons |
| CCD-900-CW |
Stulz AC, Water Cooled, 10 Ton unit, 480 Volt, 3 phase, Humidifier, Reheat Condensate pump, Mfg date 03/06, downflow. |
10 |
Liebert Condensers
| Part Number |
Description |
Tons |
| PB-1100A |
Piggy back condenser, sized for 20 Ton units, New Surplus, inside installation required for this type of solution, high rise building or any building which approves of vents for air transmission. |
20 |
| PB-550A |
Piggy back condenser, sized for 12 Ton units, New Surplus, inside installation required for this type of solution, high rise building or any building which approves of vents for air transmission. |
12 |
| PB-350A |
Piggy back condenser, sized for 8 Ton units, New Surplus, inside installation required for this type of solution, high rise building or any building which approves of vents for air transmission. |
8 |
| CSF-083L |
1 fan take/out, Mfg 98 |
5 |
| MDL RC60339 |
2 fan 460 volt, 3 phase take/out |
5 |
Liebert Dry Cooling Systems
| Part Number |
Description |
Tons |
| DDO260A |
Warehoused Indiana |
15 |
| DSO-310Y |
3 fan New surplus, Denver |
20 |
| PD-290 |
Piggyback Drycoolers, 208 Volt, 3 phase |
20 |
Liebert Glycool Pumps
| Part Number |
Description |
Tons |
|
Dual 1.5 HP |
|
|
Dual 2 HP |
|
Liebert Mini Mates
| Part Number |
Description |
Tons |
| MMD-36E |
Liebert Mini Mate, Includes MCD-38W, water cooled |
3 |
| MMD-24E |
Liebert Mini Mate, Includes MCD-26W, water cooled |
2 |
| MCD65 |
Liebert Mini Mate, Includes MMD60E, condenser |
5 |
Computer room is a location where you can find the computer network and server infrastructure of a data center. In order to maintain the performance and reliability of the entire system, controlled temperature is essential. To avoid overheating and displace heat from the computer room, air conditioners are a powerful solution.
We at Computer Facility Consultants understand the need for computer room air conditioning systems. Our used data center air conditioners are a great alternative to new air conditioning systems. Here in our online shop, you will have the chance to get precision cooling systems for the right price! Aside from offering our air conditioners at the lowest price, we never comprise our standard for quality. All the air conditioning equipment are refurbished and tested first for you to have the confidence of getting only the most reliable and cost-effective cooling system.
Our online store is filled with many used data center air conditioning systems to solve a variety of computer room heat load conditions. We carry some of the top brands such as Data Aire and Liebert. With our wide selection of branded used computer room aircons, you are sure to get the perfect system for your needs. |